PT-2022-21872 · Hiwin · Hiwin Robot System

·

CVE-2022-3382

·

Published

2022-10-17

·

Updated

2022-10-21

CVSS v3.1

7.5

High

VectorAV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Name of the Vulnerable Software and Affected Versions HIWIN Robot System Software version 3.3.21.9869
Description The issue arises from the software's failure to properly address the terminated command source. This allows an attacker to craft code that can disconnect the HIWIN Robot System Software (HRSS) and the controller, resulting in a denial-of-service condition.
Recommendations For HIWIN Robot System Software version 3.3.21.9869, consider temporarily restricting access to the command source to minimize the risk of exploitation until a patch is available. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Exploit

Improper Access Control

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2022-3382

Affected Products

Hiwin Robot System