PT-2022-23465 · Seiko · Seiko Skybridge Mb-A100/A110
Published
2022-08-29
·
Updated
2022-09-02
·
CVE-2022-36556
CVSS v3.1
9.8
Critical
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
Seiko SkyBridge MB-A100/A110 versions 4.2.0 and below
Description
A command injection issue was discovered via the
ipAddress parameter at the "/07system08execute ping 01" endpoint. This allows for potential command injection attacks.Recommendations
For Seiko SkyBridge MB-A100/A110 versions 4.2.0 and below, consider restricting access to the "/07system08execute ping 01" endpoint to minimize the risk of exploitation. Avoid using the
ipAddress parameter in this endpoint until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Command Injection
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Seiko Skybridge Mb-A100/A110