PT-2022-23465 · Seiko · Seiko Skybridge Mb-A100/A110

Published

2022-08-29

·

Updated

2022-09-02

·

CVE-2022-36556

CVSS v3.1

9.8

Critical

VectorAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Seiko SkyBridge MB-A100/A110 versions 4.2.0 and below
Description A command injection issue was discovered via the ipAddress parameter at the "/07system08execute ping 01" endpoint. This allows for potential command injection attacks.
Recommendations For Seiko SkyBridge MB-A100/A110 versions 4.2.0 and below, consider restricting access to the "/07system08execute ping 01" endpoint to minimize the risk of exploitation. Avoid using the ipAddress parameter in this endpoint until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Command Injection

Weakness Enumeration

Related Identifiers

CVE-2022-36556

Affected Products

Seiko Skybridge Mb-A100/A110