PT-2022-26001 · Delta Electronics · Infrasuite Device Master

Kimiya

·

Published

2022-10-27

·

Updated

2022-11-02

·

CVE-2022-41644

CVSS v3.1

8.8

High

VectorAV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Delta Electronics InfraSuite Device Master versions 00.00.01a and prior
Description The issue lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
Recommendations For Delta Electronics InfraSuite Device Master versions 00.00.01a and prior, consider restricting access to the function that changes group privileges until a patch is available. As a temporary workaround, disabling the function that allows privilege changes may help minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Missing Authentication

Weakness Enumeration

Related Identifiers

CVE-2022-41644
ZDI-22-1486

Affected Products

Infrasuite Device Master