PT-2022-5650 · Omron · Omron Cx-Position
Xina1I
·
Published
2022-03-29
·
Updated
2022-04-08
·
CVE-2022-26417
CVSS v3.1
7.8
High
| Vector | AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
Omron CX-Position versions 2.5.3 and prior
Description
The issue is related to a use after free memory condition that occurs while processing a specific project file. This can potentially allow an attacker to execute arbitrary code using a specially crafted file.
Recommendations
For Omron CX-Position versions 2.5.3 and prior, consider avoiding the use of specific project files that may trigger the use after free memory condition until a patch is available.
At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Use After Free
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products