Name of the Vulnerable Software and Affected Versions
Hytec Inter HWL-2511-SS version 1.05 and below
Description
The issue is related to a command injection vulnerability via the component /www/cgi-bin/popen.cgi. This vulnerability is associated with the lack of data sanitization at the management level, which can allow a remote attacker to execute arbitrary commands.
Recommendations
For Hytec Inter HWL-2511-SS version 1.05 and below, consider disabling access to the /www/cgi-bin/popen.cgi component until a patch is available. Restricting access to this component can help minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.