PT-2023-11632 · Ruckus · Smartzone 300+12
Published
2023-01-20
·
Updated
2024-08-06
·
CVE-2020-22658
CVSS v3.1
9.8
Critical
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
Ruckus R310 version 10.5.1.0.199
Ruckus R500 version 10.5.1.0.199
Ruckus R600 version 10.5.1.0.199
Ruckus T300 version 10.5.1.0.199
Ruckus T301n version 10.5.1.0.199
Ruckus T301s version 10.5.1.0.199
SmartCell Gateway 200 (SCG200) versions prior to 3.6.2.0.795
SmartZone 100 (SZ-100) versions prior to 3.6.2.0.795
SmartZone 300 (SZ300) versions prior to 3.6.2.0.795
Virtual SmartZone (vSZ) versions prior to 3.6.2.0.795
ZoneDirector 1100 version 9.10.2.0.130
ZoneDirector 1200 version 10.2.1.0.218
ZoneDirector 3000 version 10.2.1.0.218
ZoneDirector 5000 version 10.0.1.0.151
Description
A vulnerability allows attackers to switch completely to an unauthorized image to be booted as the primary verified image.
Recommendations
For Ruckus R310 version 10.5.1.0.199, update to a version later than 10.5.1.0.199.
For Ruckus R500 version 10.5.1.0.199, update to a version later than 10.5.1.0.199.
For Ruckus R600 version 10.5.1.0.199, update to a version later than 10.5.1.0.199.
For Ruckus T300 version 10.5.1.0.199, update to a version later than 10.5.1.0.199.
For Ruckus T301n version 10.5.1.0.199, update to a version later than 10.5.1.0.199.
For Ruckus T301s version 10.5.1.0.199, update to a version later than 10.5.1.0.199.
For SmartCell Gateway 200 (SCG200) versions prior to 3.6.2.0.795, update to version 3.6.2.0.795 or later.
For SmartZone 100 (SZ-100) versions prior to 3.6.2.0.795, update to version 3.6.2.0.795 or later.
For SmartZone 300 (SZ300) versions prior to 3.6.2.0.795, update to version 3.6.2.0.795 or later.
For Virtual SmartZone (vSZ) versions prior to 3.6.2.0.795, update to version 3.6.2.0.795 or later.
For ZoneDirector 1100 version 9.10.2.0.130, update to a version later than 9.10.2.0.130.
For ZoneDirector 1200 version 10.2.1.0.218, update to a version later than 10.2.1.0.218.
For ZoneDirector 3000 version 10.2.1.0.218, update to a version later than 10.2.1.0.218.
For ZoneDirector 5000 version 10.0.1.0.151, update to a version later than 10.0.1.0.151.
Fix
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Ruckus R310
Ruckus R500
Ruckus R600
Ruckus T300
Ruckus T301S
Smartcell Gateway 200
Smartzone 100
Smartzone 300
Virtual Smartzone
Zonedirector 1100
Zonedirector 1200
Zonedirector 3000
Zonedirector 5000