PT-2023-14601 · Siemens · Sinec Ins
Published
2023-01-10
·
Updated
2023-01-14
·
CVE-2022-45093
CVSS v3.1
8.8
High
| Vector | AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
SINEC INS versions prior to V1.0 SP2 Update 1
Description
A vulnerability has been identified that allows an authenticated remote attacker with access to the Web Based Management (443/tcp) and the SFTP server (22/tcp) to potentially read and write arbitrary files from and to the device's file system. This could be leveraged to trigger remote code execution on the affected component.
Recommendations
For versions prior to V1.0 SP2 Update 1, update to V1.0 SP2 Update 1 or later to resolve the issue. As a temporary workaround, consider restricting access to the Web Based Management and SFTP server to minimize the risk of exploitation.
Fix
Path traversal
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Sinec Ins