PT-2023-15852 · Sciencelogic · Sciencelogic Sl1
Christian Weiler
·
Published
2023-08-09
·
Updated
2023-08-25
·
CVE-2022-48580
CVSS v3.1
8.8
High
| Vector | AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
ScienceLogic SL1 (affected versions not specified)
Description
A command injection issue exists in the ARP ping device tool feature of the ScienceLogic SL1. This feature takes unsanitized user-controlled input and passes it directly to a shell command, allowing for the injection of arbitrary commands to the underlying operating system.
Recommendations
At the moment, there is no information about a newer version that contains a fix for this vulnerability.
OS Command Injection
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Sciencelogic Sl1