PT-2023-18499 · Seiko Solutions · Seiko Solutions Skybridge Mb-A200+1
Samy Younsi
+1
·
Published
2023-05-10
·
Updated
2025-01-28
·
CVE-2023-22441
CVSS v3.1
8.6
High
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H |
Name of the Vulnerable Software and Affected Versions
Seiko Solutions SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier
Seiko Solutions SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
Description
A missing authentication issue for a critical function exists in the Seiko Solutions SkyBridge series, allowing a remote attacker to obtain or alter the product's setting information or execute critical functions without authentication, such as rebooting the product.
Recommendations
For Seiko Solutions SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, update to a version later than Ver. 01.00.05 to resolve the issue.
For Seiko Solutions SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, update to a version later than Ver. 1.4.1 to resolve the issue.
As a temporary workaround, consider restricting access to critical functions that do not require authentication until a patch is available.
Fix
Missing Authentication
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Seiko Solutions Skybridge Basic Mb-A130
Seiko Solutions Skybridge Mb-A200