PT-2023-2323 · Delta Electronics · Infrasuite Device Master

Chudypd

+1

·

Published

2023-03-21

·

Updated

2023-05-17

·

CVE-2023-1137

CVSS v2.0

9.0

High

VectorAV:N/AC:L/Au:S/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions Delta Electronics InfraSuite Device Master versions prior to 1.0.5
Description The issue is related to insufficient input validation, allowing a low-level user to extract files and plaintext credentials of administrator users. This results in privilege escalation. The vulnerability can be exploited by a remote attacker to elevate their privileges.
Recommendations For versions prior to 1.0.5, update to version 1.0.5 or later to resolve the issue. As a temporary workaround, consider restricting access to sensitive files and administrator credentials to minimize the risk of exploitation.

Fix

Insufficiently Protected Credentials

Improper Access Control

Weakness Enumeration

Related Identifiers

BDU:2023-02088
CVE-2023-1137
ZDI-23-685

Affected Products

Infrasuite Device Master