PT-2023-31546 · Goodix+2 · Goodix Fingerprint Device+2

0X30N

+3

·

Published

2023-12-09

·

Updated

2023-12-13

·

CVE-2023-50430

CVSS v3.1

6.4

Medium

VectorAV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Goodix Fingerprint Device (affected versions not specified) Dell Inspiron 15 computers (affected versions not specified)
Description The Goodix Fingerprint Device does not follow the Secure Device Connection Protocol (SDCP) when enrolling via Linux. It accepts an unauthenticated configuration packet to select the Windows template database, allowing bypass of Windows Hello authentication by enrolling an attacker's fingerprint.
Recommendations For the Goodix Fingerprint Device, consider disabling the enrollment feature via Linux until a patch is available. For Dell Inspiron 15 computers, restrict access to the fingerprint enrollment process to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Exploit

Improper Authentication

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2023-50430

Affected Products

Dell Inspiron 15
Goodix Fingerprint Device
Windows Shell