PT-2023-3254 · Siemens · Tecnomatix Plant Simulation

Published

2023-02-14

·

Updated

2023-02-24

·

CVE-2023-24987

CVSS v3.1

7.8

High

VectorAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Tecnomatix Plant Simulation versions prior to V2201.0006
Description The issue is related to an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.
Recommendations For versions prior to V2201.0006, update to version V2201.0006 or later to resolve the issue. As a temporary workaround, consider restricting the use of specially crafted SPP files until a patch is available. Avoid using the affected SPP file parsing functionality in the vulnerable versions of Tecnomatix Plant Simulation to minimize the risk of exploitation.

Fix

Memory Corruption

Weakness Enumeration

Related Identifiers

BDU:2023-03375
CVE-2023-24987
ZDI-23-195

Affected Products

Tecnomatix Plant Simulation