PT-2023-4360 · Triangle Microworks · Scada Data Gateway

Noam Moshe

+3

·

Published

2023-08-04

·

Updated

2024-05-05

·

CVE-2023-39460

CVSS v2.0

8.3

High

VectorAV:N/AC:L/Au:M/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions Triangle MicroWorks SCADA Data Gateway (affected versions not specified)
Description The issue is related to incorrect restriction of a directory path with limited access. This can be exploited by a remote attacker to execute arbitrary code in the context of root. The vulnerability exists within the creation of event logs due to the lack of proper validation of a user-supplied path prior to using it in file operations. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root.
Recommendations At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Path traversal

Weakness Enumeration

Related Identifiers

BDU:2023-04705
CVE-2023-39460
ZDI-23-1028

Affected Products

Scada Data Gateway