PT-2023-5213 · Schweitzer Engineering Laboratories · Acselerator Quickset

Gabriele Quagliarella

·

Published

2023-06-15

·

Updated

2023-09-05

·

CVE-2023-31169

CVSS v3.1

5.7

Medium

VectorAV:N/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N
Name of the Vulnerable Software and Affected Versions Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software versions through 7.1.3.0
Description The issue is related to an improper handling of Unicode encoding, which could allow an attacker to embed instructions that could be executed by an authorized device operator. This could potentially enable a remote attacker to execute arbitrary code. For more details, refer to the Instruction Manual Appendix A and Appendix E dated 20230615.
Recommendations For versions through 7.1.3.0, update to a version that addresses the improper handling of Unicode encoding issue, as described in the Instruction Manual Appendix A and Appendix E dated 20230615. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Improper Handling of Exceptional Conditions

Weakness Enumeration

Related Identifiers

BDU:2023-05821
CVE-2023-31169

Affected Products

Acselerator Quickset