PT-2023-5308 · Siemens · Teamcenter Visualization+1
Published
2023-08-08
·
Updated
2024-08-13
·
CVE-2023-38527
CVSS v3.1
7.8
High
| Vector | AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
Parasolid versions prior to V34.1.258
Parasolid versions prior to V35.0.254
Teamcenter Visualization version V14.1
Teamcenter Visualization versions prior to V14.2.0.12
Teamcenter Visualization versions prior to V14.3.0.9
Teamcenter Visualization versions prior to V2312.0004
Description
The issue is related to an out of bounds read past the end of an allocated structure while parsing specially crafted X T files. This could allow an attacker to execute code in the context of the current process. The vulnerability is associated with reading data beyond buffer boundaries in memory, which may enable an attacker to execute arbitrary code.
Recommendations
For Parasolid versions prior to V34.1.258, update to version V34.1.258 or later.
For Parasolid versions prior to V35.0.254, update to version V35.0.254 or later.
For Teamcenter Visualization version V14.1, consider disabling the parsing of X T files until a patch is available.
For Teamcenter Visualization versions prior to V14.2.0.12, update to version V14.2.0.12 or later.
For Teamcenter Visualization versions prior to V14.3.0.9, update to version V14.3.0.9 or later.
For Teamcenter Visualization versions prior to V2312.0004, update to version V2312.0004 or later.
As a temporary workaround, consider restricting access to the affected applications to minimize the risk of exploitation.
Fix
Out of bounds Read
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Parasolid