PT-2023-5409 · Siemens · Teamcenter Visualization+1

Jin Huang

·

Published

2023-08-08

·

Updated

2024-08-13

·

CVE-2023-38529

CVSS v3.1

7.8

High

VectorAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Parasolid versions prior to V34.1.258 Parasolid versions prior to V35.0.254 Parasolid versions prior to V35.1.184 Teamcenter Visualization versions prior to V14.2.0.12 Teamcenter Visualization versions prior to V14.3.0.9 Teamcenter Visualization versions prior to V2312.0004
Description The issue is related to an out of bounds read past the end of an allocated structure while parsing specially crafted X T files. This could allow an attacker to execute code in the context of the current process. The vulnerability is associated with a buffer read beyond the memory boundary, which can be exploited using specially created files.
Recommendations For Parasolid versions prior to V34.1.258, update to version V34.1.258 or later. For Parasolid versions prior to V35.0.254, update to version V35.0.254 or later. For Parasolid versions prior to V35.1.184, update to version V35.1.184 or later. For Teamcenter Visualization versions prior to V14.2.0.12, update to version V14.2.0.12 or later. For Teamcenter Visualization versions prior to V14.3.0.9, update to version V14.3.0.9 or later. For Teamcenter Visualization versions prior to V2312.0004, update to version V2312.0004 or later.

Fix

Out of bounds Read

Weakness Enumeration

Related Identifiers

BDU:2023-06039
CVE-2023-38529

Affected Products

Parasolid
Teamcenter Visualization