PT-2023-5571 · Siemens · Siemens Software Center

Published

2023-08-08

·

Updated

2023-08-15

·

CVE-2021-41544

CVSS v3.1

7.8

High

VectorAV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Siemens Software Center versions prior to V3.0
Description A DLL Hijacking issue could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path. This is related to an uncontrolled search path element. Exploitation may enable an attacker to run arbitrary code with increased privileges using a specially crafted dll file.
Recommendations For versions prior to V3.0, update to version V3.0 or later to resolve the issue. As a temporary workaround, consider restricting access to directories on the DLL search path to minimize the risk of exploitation.

Fix

Uncontrolled Search Path Element

Weakness Enumeration

Related Identifiers

BDU:2023-06222
CVE-2021-41544

Affected Products

Siemens Software Center