PT-2023-7821 · Schneider Electric · Apc Easy Ups Online Monitoring
Published
2023-12-12
·
Updated
2023-12-18
·
CVE-2023-6407
CVSS v3.1
7.1
High
| Vector | AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
APC Easy UPS Online Monitoring Software (affected versions not specified)
Description
The issue is related to improper limitation of a pathname to a restricted directory, also known as a 'Path Traversal' vulnerability. This could allow an attacker to delete arbitrary files upon service restart, especially when accessed by a local and low-privileged attacker.
Recommendations
At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Path traversal
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Apc Easy Ups Online Monitoring