PT-2024-10040 · Siemens · Teamcenter Visualization+1

Published

2024-10-08

·

Updated

2024-12-10

·

CVE-2024-45466

CVSS v3.1

7.8

High

VectorAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Teamcenter Visualization versions prior to V14.2.0.14 Teamcenter Visualization versions prior to V14.3.0.12 Teamcenter Visualization versions prior to V2312.0008 Tecnomatix Plant Simulation versions prior to V2302.0016 Tecnomatix Plant Simulation versions prior to V2404.0005
Description The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. The vulnerability is related to a memory read issue that can be exploited to execute arbitrary code.
Recommendations For Teamcenter Visualization versions prior to V14.2.0.14, update to version V14.2.0.14 or later. For Teamcenter Visualization versions prior to V14.3.0.12, update to version V14.3.0.12 or later. For Teamcenter Visualization versions prior to V2312.0008, update to version V2312.0008 or later. For Tecnomatix Plant Simulation versions prior to V2302.0016, update to version V2302.0016 or later. For Tecnomatix Plant Simulation versions prior to V2404.0005, update to version V2404.0005 or later.

Fix

Out of bounds Read

Weakness Enumeration

Related Identifiers

BDU:2025-00178
CVE-2024-45466

Affected Products

Teamcenter Visualization
Tecnomatix Plant Simulation