PT-2024-19510 · Setor Informatica · Setor Informatica Sistema Inteligente Para Laboratorios
Elizeu
·
Published
2024-04-26
·
Updated
2024-08-08
·
CVE-2024-22633
CVSS v3.1
9.8
Critical
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
Setor Informatica Sistema Inteligente para Laboratorios (S.I.L.) version 388
Description
The issue is related to a remote code execution (RCE) vulnerability. It can be triggered via a crafted POST request to the
hprinter parameter.Recommendations
For Setor Informatica Sistema Inteligente para Laboratorios (S.I.L.) version 388, as a temporary workaround, consider restricting access to the
hprinter parameter until a patch is available. Avoid using the hprinter parameter in affected API endpoints until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Code Injection