PT-2024-2264 · Tenda · Tenda Ac18
Yhryhryhr
·
Published
2024-03-05
·
Updated
2025-01-14
·
CVE-2024-2485
CVSS v2.0
9.0
High
| Vector | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Tenda AC18 version 15.03.05.05
Description
A critical issue was found in the function
formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed dir leads to a stack-based buffer overflow. This issue can be exploited remotely, potentially affecting the confidentiality, integrity, and availability of protected information.Recommendations
For Tenda AC18 version 15.03.05.05, as a temporary workaround, consider disabling the
formSetSpeedWan function until a patch is available. Restrict access to the /goform/SetSpeedWan endpoint to minimize the risk of exploitation. Avoid using the parameter speed dir in the affected endpoint until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this issue.Exploit
Fix
Memory Corruption
Stack Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Related Identifiers
Affected Products
Tenda Ac18