PT-2024-2351 · Tenda · Tenda Ac10
Yhryhryhr_Mie
·
Published
2024-03-20
·
Updated
2024-12-12
·
CVE-2024-2709
CVSS v2.0
9.0
High
| Vector | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Tenda AC10U version 15.03.06.49
Description
The issue is related to a stack-based buffer overflow in the
fromSetRouteStatic function of the /goform/SetStaticRouteCfg file. This can be exploited remotely, potentially affecting the confidentiality, integrity, and availability of protected information. The manipulation of the list argument leads to this buffer overflow. It is possible to launch the attack remotely.Recommendations
For Tenda AC10U version 15.03.06.49, as a temporary workaround, consider disabling the
fromSetRouteStatic function until a patch is available. Restrict access to the /goform/SetStaticRouteCfg file to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploit
Memory Corruption
Stack Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Related Identifiers
Affected Products
Tenda Ac10