PT-2024-2394 · Tenda · Tenda Ac10

Wxhwxhwxh_Miemie

·

Published

2024-03-16

·

Updated

2024-05-17

·

CVE-2024-2853

CVSS v2.0

10

Critical

VectorAV:N/AC:L/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions Tenda AC10U versions 15.03.06.48 through 15.03.06.49
Description A critical issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely.
Recommendations For Tenda AC10U versions 15.03.06.48 through 15.03.06.49, as a temporary workaround, consider disabling the formSetSambaConf function until a patch is available. Restrict access to the /goform/setsambacfg file to minimize the risk of exploitation. Avoid using the parameter usbName in the affected API endpoint until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Exploit

OS Command Injection

Weakness Enumeration

Related Identifiers

BDU:2024-02346
CVE-2024-2853

Affected Products

Tenda Ac10