PT-2024-2492 · Tenda · Tenda Ac7
Wxhwxhwxh_Tutu
·
Published
2024-03-18
·
Updated
2025-01-22
·
CVE-2024-2902
CVSS v2.0
9.0
High
| Vector | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Tenda AC7 version 15.03.06.44
Description
A critical issue affects the
fromSetWifiGusetBasic function of the /goform/WifiGuestSet file, leading to a stack-based buffer overflow due to the manipulation of the shareSpeed argument. This can be exploited remotely, potentially impacting the confidentiality, integrity, and availability of protected information. The issue can be triggered by a specially crafted POST request.Recommendations
For Tenda AC7 version 15.03.06.44, consider disabling the
fromSetWifiGusetBasic function as a temporary workaround until a patch is available. Restrict access to the /goform/WifiGuestSet file to minimize the risk of exploitation. Avoid using the shareSpeed argument in the affected API endpoint until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploit
Memory Corruption
Stack Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Related Identifiers
Affected Products
Tenda Ac7