PT-2024-2598 · Tenda · Tenda Ac7
Wxhwxhwxh_Tutu
·
Published
2024-03-26
·
Updated
2025-01-22
·
CVE-2024-2894
CVSS v2.0
9.0
High
| Vector | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Tenda AC7 version 15.03.06.44
Description
The issue is caused by a stack-based buffer overflow in the
formSetQosBand function of the /goform/SetNetControlList file. This can be exploited remotely, potentially affecting the confidentiality, integrity, and availability of protected information. The manipulation of the list argument leads to the buffer overflow. The exploit has been disclosed publicly and may be used.Recommendations
For Tenda AC7 version 15.03.06.44, as a temporary workaround, consider disabling the
formSetQosBand function until a patch is available. Restrict access to the /goform/SetNetControlList API endpoint to minimize the risk of exploitation. Avoid using the list argument in the affected API endpoint until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploit
Memory Corruption
Stack Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Related Identifiers
Affected Products
Tenda Ac7