PT-2024-2877 · Tenda · Tenda Ac500
Yhryhryhr_Tu
·
Published
2024-04-10
·
Updated
2025-01-21
·
CVE-2024-3906
CVSS v2.0
9.0
High
| Vector | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Tenda AC500 version 2.0.1.9(1307)
Description
A critical issue affects the
formQuickIndex function of the /goform/QuickIndex file, leading to a stack-based buffer overflow when the PPPOEPassword argument is manipulated. This can be exploited remotely, potentially allowing an attacker to execute arbitrary code using a specially crafted POST request.Recommendations
For Tenda AC500 version 2.0.1.9(1307), as a temporary workaround, consider disabling the
formQuickIndex function until a patch is available. Restrict access to the /goform/QuickIndex file to minimize the risk of exploitation. Avoid using the PPPOEPassword argument in the affected API endpoint until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploit
Memory Corruption
Stack Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Related Identifiers
Affected Products
Tenda Ac500