PT-2024-29690 · Atos · Atos Eviden Smc Xscale
Published
2024-10-11
·
Updated
2024-11-06
·
CVE-2024-42018
CVSS v3.1
7.7
High
| Vector | AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N |
Name of the Vulnerable Software and Affected Versions
Atos Eviden SMC xScale versions prior to 1.6.6
Description
An issue was discovered in Atos Eviden SMC xScale during initialization of nodes, where some configuration parameters are retrieved from management nodes. These parameters embed credentials whose integrity and confidentiality may be important to the security of the HPC configuration. Because these parameters are needed for initialization, there is no available mechanism to ensure access control on the management node, and a mitigation measure is normally put in place to prevent access to unprivileged users. It was discovered that this mitigation measure does not survive a reboot of diskful nodes. The mistake lies in the cloudinit configuration, where the iptables configuration should have been in the bootcmd instead of the runcmd section.
Recommendations
For Atos Eviden SMC xScale versions prior to 1.6.6, update to version 1.6.6 or later to resolve the issue. As a temporary workaround, consider modifying the cloudinit configuration to move the iptables configuration from the runcmd section to the bootcmd section to prevent access to unprivileged users after a reboot.
Fix
Insecure Storage of Sensitive Information
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Atos Eviden Smc Xscale