PT-2024-30224 · Tenda · Tenda Fh1201
Published
2024-08-15
·
Updated
2024-08-19
·
CVE-2024-42954
CVSS v3.1
7.5
High
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
Name of the Vulnerable Software and Affected Versions
Tenda FH1201 version 1.2.0.14
Description
The issue is related to a stack overflow vulnerability via the
page parameter in the fromwebExcptypemanFilter function. This allows attackers to cause a Denial of Service (DoS) via a crafted POST request.Recommendations
For Tenda FH1201 version 1.2.0.14, consider disabling the
fromwebExcptypemanFilter function as a temporary workaround until a patch is available. Restrict access to the vulnerable function to minimize the risk of exploitation. Avoid using the page parameter in affected API endpoints until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploit
Memory Corruption
Stack Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Related Identifiers
Affected Products
Tenda Fh1201