PT-2024-3255 · Tenda · Tenda I21

Yhryhryhr_Miemie

·

Published

2024-04-27

·

Updated

2024-06-04

·

CVE-2024-4491

CVSS v2.0

9.0

High

VectorAV:N/AC:L/Au:S/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions Tenda i21 version 1.0.0.14(4656)
Description A critical vulnerability was found in the function formGetDiagnoseInfo of the Tenda i21 software. The manipulation of the argument cmdinput leads to a stack-based buffer overflow. This issue can be exploited remotely, potentially affecting the confidentiality, integrity, and availability of protected information. The exploit has been disclosed to the public and may be used. The vendor was contacted about this disclosure but did not respond.
Recommendations As a temporary workaround, consider disabling the formGetDiagnoseInfo function until a patch is available. Restrict access to the cmdinput argument to minimize the risk of exploitation. Avoid using the cmdinput argument in the affected function until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Exploit

Memory Corruption

Stack Overflow

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

BDU:2024-03486
CVE-2024-4491

Affected Products

Tenda I21