PT-2024-3768 · Tenda · Tenda W30E
Wxhwxhwxh_Mie
·
Published
2024-04-16
·
Updated
2025-01-27
·
CVE-2024-3881
CVSS v2.0
9.0
High
| Vector | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Tenda W30E version 1.0.1.25(633)
Description
The issue is related to a stack-based buffer overflow in the
frmL7PlotForm function of the file /goform/frmL7ProtForm. This can be exploited by manipulating the page argument, allowing a remote attacker to impact the confidentiality, integrity, and availability of protected information. The attack can be initiated remotely using a specially crafted POST request.Recommendations
For Tenda W30E version 1.0.1.25(633), consider disabling the
frmL7PlotForm function until a patch is available. Restrict access to the /goform/frmL7ProtForm file to minimize the risk of exploitation. Avoid using the page argument in the affected API endpoint until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploit
Memory Corruption
Stack Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Related Identifiers
Affected Products
Tenda W30E