PT-2024-5046 · Rockwell Automation · Rockwell Automation Factorytalk Remote Access

CVE-2024-3640

·

Published

2024-05-14

·

Updated

2024-09-20

CVSS v4.0

7.0

High

VectorAV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Name of the Vulnerable Software and Affected Versions: Rockwell Automation FactoryTalk Remote Access (affected versions not specified)
Description: The issue is related to an unquoted executable path in the Rockwell Automation FactoryTalk Remote Access, which could result in remote code execution if exploited. This occurs because the executable path is not properly quoted while running the installer package, allowing a threat actor to potentially enter a malicious executable and run it as a System user. Exploitation requires admin privileges. There have been reports of this issue being exploited in real-world attacks, including a case where a government organization in Taiwan was targeted using spear-phishing emails.
Recommendations: At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

BDU:2024-05573
CVE-2024-3640

Affected Products

Rockwell Automation Factorytalk Remote Access