PT-2024-7414 · Siemens · Simatic Step 7 Safety
Published
2024-07-09
·
Updated
2024-07-09
·
CVE-2023-32737
CVSS v3.1
6.3
Medium
| Vector | AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions:
SIMATIC STEP 7 Safety versions prior to V18 Update 2
Description:
The issue is related to the improper restriction of the .NET BinaryFormatter when deserializing user-controllable input, which could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is similar to the issue that exists for .NET BinaryFormatter.
Recommendations:
For versions prior to V18 Update 2, update to V18 Update 2 to resolve the issue. As a temporary workaround, consider restricting the use of the .NET BinaryFormatter when deserializing user-controllable input to minimize the risk of exploitation.
Fix
Deserialization of Untrusted Data