PT-2024-7415 · Siemens · Siemens Sinec Security Monitor

Published

2024-08-10

·

Updated

2024-10-13

·

CVE-2024-47553

CVSS v3.1

9.9

Critical

VectorAV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions: Siemens SINEC Security Monitor versions prior to V4.9.0
Description: The issue is related to the incorrect processing of user input data in the ssmctl-client command, which could allow a remote attacker to execute arbitrary code with root privileges on the underlying operating system. This is due to the affected application not properly validating user input to the ssmctl-client command.
Recommendations: For versions prior to V4.9.0, update to version V4.9.0 or later to resolve the issue. As a temporary workaround, consider restricting access to the ssmctl-client command to minimize the risk of exploitation.

Fix

Argument Injection

Weakness Enumeration

Related Identifiers

BDU:2024-08789
CVE-2024-47553

Affected Products

Siemens Sinec Security Monitor