PT-2024-8739 · Siemens · Teamcenter Visualization+1
Published
2024-11-18
·
Updated
2024-12-10
·
CVE-2024-52568
CVSS v3.1
7.8
High
| Vector | AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
Teamcenter Visualization versions prior to V14.2.0.14
Teamcenter Visualization versions prior to V14.3.0.12
Teamcenter Visualization versions prior to V2312.0008
Teamcenter Visualization versions prior to V2406.0005
Tecnomatix Plant Simulation versions prior to V2302.0018
Tecnomatix Plant Simulation versions prior to V2404.0007
Description
The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.
Recommendations
For Teamcenter Visualization versions prior to V14.2.0.14, update to version V14.2.0.14 or later.
For Teamcenter Visualization versions prior to V14.3.0.12, update to version V14.3.0.12 or later.
For Teamcenter Visualization versions prior to V2312.0008, update to version V2312.0008 or later.
For Teamcenter Visualization versions prior to V2406.0005, update to version V2406.0005 or later.
For Tecnomatix Plant Simulation versions prior to V2302.0018, update to version V2302.0018 or later.
For Tecnomatix Plant Simulation versions prior to V2404.0007, update to version V2404.0007 or later.
As a temporary workaround, consider restricting the use of WRL files in the affected applications until a patch is available.
Fix
Use After Free
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Teamcenter Visualization