PT-2024-8755 · Siemens · Simcenter Femap

Published

2024-05-14

·

Updated

2024-07-09

·

CVE-2024-32063

CVSS v3.1

7.8

High

VectorAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Simcenter Femap versions prior to V2406
Description A type confusion vulnerability has been identified in the affected application while parsing IGS files. This could allow an attacker to execute code in the context of the current process by using specially crafted IGS files.
Recommendations For versions prior to V2406, update to version V2406 or later to resolve the issue. As a temporary workaround, consider avoiding the use of IGS files from untrusted sources until the issue is resolved. Restrict access to the IGS file parsing functionality to minimize the risk of exploitation.

Fix

Type Confusion

Weakness Enumeration

Related Identifiers

BDU:2024-10359
CVE-2024-32063
ZDI-24-462

Affected Products

Simcenter Femap