PT-2025-14837 · Code Projects · Patient Record Management System
Zokeye
·
Published
2025-04-04
·
Updated
2025-04-08
·
CVE-2025-3208
CVSS v3.1
7.5
High
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
Name of the Vulnerable Software and Affected Versions
code-projects Patient Record Management System version 1.0
code-projects Patient Record Management System version 3.1
Description
A critical issue was found in the Patient Record Management System. The manipulation of the
itr no argument in the /xray print.php file leads to SQL injection. This issue can be exploited remotely.Recommendations
For version 1.0, consider restricting access to the
/xray print.php file to minimize the risk of exploitation.
For version 3.1, avoid using the itr no argument in the affected API endpoint until the issue is resolved.
At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploit
Special Elements Injection
SQL injection
Found an issue in the description? Have something to add? Feel free to write us 👾