PT-2025-21759 · Tenda · Tenda Ac7

Yhryhryhr_Miemie

·

Published

2025-05-16

·

Updated

2025-05-25

·

CVE-2025-4809

CVSS v2.0

9.0

High

VectorAV:N/AC:L/Au:S/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions: Tenda AC7 version 15.03.06.44
Description: A critical issue was found in the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to a stack-based buffer overflow. This issue can be exploited remotely.
Recommendations: For Tenda AC7 version 15.03.06.44, as a temporary workaround, consider disabling the fromSafeSetMacFilter function until a patch is available. Restrict access to the /goform/setMacFilterCfg file to minimize the risk of exploitation. Avoid using the deviceList argument in the affected function until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Exploit

Memory Corruption

Stack Overflow

Buffer Overflow

Weakness Enumeration

Related Identifiers

BDU:2025-05874
CVE-2025-4809

Affected Products

Tenda Ac7