PT-2025-21922 · V-Sft · V-Sft

Michael Heinzl

·

Published

2025-05-14

·

Updated

2025-05-19

·

CVE-2025-47757

CVSS v3.1

7.8

High

VectorAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions: V-SFT versions 6.2.5.0 and earlier
Description: The issue is related to an out-of-bounds read in the set plc type default function of the VS6MemInIF.dll module. This can be triggered by opening specially crafted V7 or V8 files, potentially leading to a crash, information disclosure, and arbitrary code execution.
Recommendations: For V-SFT versions 6.2.5.0 and earlier, consider disabling the set plc type default function in the VS6MemInIF.dll module as a temporary workaround to minimize the risk of exploitation. Avoid opening specially crafted V7 or V8 files until a patch is available. At the moment, there is no information about a newer version that contains a fix for this issue.

Fix

Out of bounds Read

Weakness Enumeration

Related Identifiers

BDU:2025-05963
CVE-2025-47757

Affected Products

V-Sft