PT-2025-2792 · Unknown · Hi-Scan 6040I

Published

2025-01-15

·

Updated

2025-01-17

·

CVE-2024-48126

CVSS v3.1

9.8

Critical

VectorAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions: HI-SCAN 6040i Hitrax HX-03-19-I
Description: The issue concerns hardcoded credentials in the system, which could allow unauthorized access to vendor support and service access.
Recommendations: For HI-SCAN 6040i Hitrax HX-03-19-I, consider changing the hardcoded credentials for vendor support and service access to unique, secure credentials to prevent unauthorized access. As a temporary workaround, restrict access to the system until secure credentials can be implemented.

Fix

Using Hardcoded Credentials

Weakness Enumeration

Related Identifiers

CVE-2024-48126

Affected Products

Hi-Scan 6040I