PT-2025-38490 · Cognex · Cognex In-Sight Explorer+1

Diego Giubertoni

·

Published

2025-09-18

·

Updated

2025-09-19

·

CVE-2025-54810

CVSS v3.1

8.0

High

VectorAV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Cognex In-Sight Explorer and In-Sight Camera Firmware (affected versions not specified)
Description The software exposes a proprietary protocol on TCP port 1069 for management operations, including modifying system properties. The user management functionality transmits sensitive data, such as usernames and passwords, over an unencrypted channel, potentially allowing an adjacent attacker to intercept credentials and gain access to the device.
Recommendations At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Weakness Enumeration

Related Identifiers

CVE-2025-54810

Affected Products

Cognex In-Sight Explorer