PT-2025-52237 · National Instruments · Ni Labview
Michael Heinzl
·
Published
2025-12-18
·
Updated
2025-12-24
·
CVE-2025-64467
CVSS v4.0
8.5
High
| Vector | AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Name of the Vulnerable Software and Affected Versions
NI LabVIEW versions prior to 25.3
Description
An out of bounds read issue exists in NI LabVIEW within the
LVResFile::FindRsrcListEntry() function when processing a damaged VI file. This can lead to information disclosure or arbitrary code execution. An attacker can exploit this by tricking a user into opening a specifically designed VI file.Recommendations
Update to NI LabVIEW version 25.3 or later.
Fix
Out of bounds Read
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Ni Labview