PT-2025-52242 · National Instruments · Ni Labview

Michael Heinzl

·

Published

2025-12-18

·

Updated

2025-12-24

·

CVE-2025-64468

CVSS v4.0

8.5

High

VectorAV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Name of the Vulnerable Software and Affected Versions NI LabVIEW versions 2025 Q3 (25.3) and prior
Description A use-after-free issue exists in the sentry span set data() function when processing a malformed VI file. Exploitation of this issue could lead to information disclosure or arbitrary code execution. Successful exploitation requires an attacker to trick a user into opening a specifically designed VI file.
Recommendations Update to a version later than 2025 Q3 (25.3).

Fix

Use After Free

Weakness Enumeration

Related Identifiers

CVE-2025-64468

Affected Products

Ni Labview