PT-2026-28750 · Belkin · Belkin F9K1122
Ltzhuster2
+1
·
Published
2026-03-29
·
Updated
2026-03-29
·
CVE-2026-5042
CVSS v2.0
9.0
High
| Vector | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Belkin F9K1122 version 1.00.33
Description
A security issue exists in Belkin F9K1122 1.00.33. The issue involves a stack-based buffer overflow in the
formCrossBandSwitch function located in the /goform/formCrossBandSwitch file within the Parameter Handler component. The overflow is triggered by manipulating the webpage argument. This allows for potential remote attacks. The exploit for this issue has been publicly released.Recommendations
Belkin F9K1122 version 1.00.33: As a temporary workaround, consider disabling the
formCrossBandSwitch function until a patch is available.Exploit
Fix
Memory Corruption
Buffer Overflow
Stack Overflow