PT-2026-30995 · Semtech · Lr11Xx Lora Transceivers

Published

2026-04-07

·

Updated

2026-04-08

·

CVE-2025-14858

CVSS v4.0

5.1

Medium

VectorAV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:N/R:A/V:C/RE:M/U:X
Name of the Vulnerable Software and Affected Versions Semtech LR11xx LoRa transceivers (affected versions not specified)
Description The Semtech LR11xx LoRa transceivers running early firmware versions has an issue where the last decrypted firmware block remains in memory after a firmware validity check. An attacker with access to the SPI interface can retrieve the decrypted firmware contents from residual memory, bypassing firmware encryption. The attack requires physical access to the device's SPI interface.
Recommendations At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Weakness Enumeration

Related Identifiers

CVE-2025-14858

Affected Products

Lr11Xx Lora Transceivers