PT-2026-31911 · Unknown · Atom 3X Projector

Published

2026-04-10

·

Updated

2026-04-12

·

CVE-2026-5777

CVSS v4.0

8.7

High

VectorAV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Name of the Vulnerable Software and Affected Versions Atom 3x Projector (affected versions not specified)
Description The Atom 3x Projector is affected by an issue due to the improper exposure of the Android Debug Bridge (ADB) service over the local network without authentication or access controls. An unauthenticated attacker on the same network can exploit this to obtain root-level access, leading to complete device compromise.
Recommendations At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Missing Authentication

Weakness Enumeration

Related Identifiers

CVE-2026-5777

Affected Products

Atom 3X Projector