PT-2026-44500 · Xcharge · C6

Published

2026-05-28

·

Updated

2026-05-28

·

CVE-2026-9039

CVSS v4.0

8.6

High

VectorAV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Name of the Vulnerable Software and Affected Versions The product name cannot be determined (affected versions not specified)
Description A configuration weakness in the remote management service allows an authenticated session to be established over a communication channel designed only for vehicle-charger signaling. This service is accessible via interfaces exposed through the charging connector and accepts default administrative credentials. A malicious device physically connected to the charging interface can exploit this misconfiguration to gain full administrative access.
Recommendations At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Weakness Enumeration

Related Identifiers

CVE-2026-9039

Affected Products

C6